Douglas DC-9-32 N838AT
8 August 2000 · Greensboro, North Carolina, United States · Minor injuries
Summary
On 8 August 2000 at about 19:44 local time, a Douglas DC-9-32 registered N838AT, operated by Airtran Airlines Inc, was involved in an accident near Greensboro, North Carolina, United States. 63 people were on board and 13 had minor injuries. The aircraft was substantially damaged. The NTSB has published a probable cause for this accident; it is quoted in full below.
The record
- Date
- at 19:44
- Classification
- Accident
- Location
- Greensboro, North Carolina, United States
- Nearest airport
- Piedmont Triad International (GSO)
- Coordinates
- Not recorded
- Aircraft
- Douglas DC-9-32
- Registration
- N838AT
- Category
- Airplane
- Engines
- 2
- Operator
- Airtran Airlines Inc
- Operating rule
- Part 121: Air Carrier
- Purpose of flight
- Unknown
- Phase of flight
- Not recorded
- Route
- Unknown → Atlanta
- Aircraft damage
- Substantial
- Weather
- VMC
- Light
- Not Reported
- NTSB number
- DCA00MA079
People
13 people had minor injuries.
| On board | Died | Serious | Minor | Uninjured |
|---|---|---|---|---|
| 63 | 0 | 0 | 13 | 50 |
Probable cause
A phase-to-phase arc in the left heat exchanger cooling fan relay, which ignited the surrounding wire insulation and other combustible materials within the electrical power center panel. Contributing to the left heat exchanger fan relay malfunction was the unauthorized repair that was not to the manufacturer's standards and the circuit breakers' failure to recognize an arc-fault.
Quoted verbatim from the NTSB record. This site does not paraphrase or interpret it.
Read the full NTSB narrative
Examination of the area of the fire origin revealed that relay R2-53, the left heat exchanger cooling fan relay, was severely heat damaged, as were R2-54 and the other relays in this area. However, the R2-53 relay also exhibited loose terminal studs and several holes that had burned through the relay housing that the other relays did not exhibit. The wire bundles that run immediately below the left and right heat exchanger cooling fans and the ground service tie relays exhibited heat damage to the wire insulation, with the greatest damage located just below the R2-53 relay. The unique damage observed on the R2-53 relay and the wire damage directly below it indicates that fire initiation was caused by an internal failure of the R2-53 relay. Disassembly of the relay revealed that the R2-53 relay had been repaired but not to the manufacturer's standards. According to the manufacturer, the damage to the relay housing was consistent with a phase-to-phase arc between terminals A2 and B2 of the relay. During the on-scene portion of the investigation, three of the four circuit breakers in the left heat exchanger cooling fan were found in the tripped position. To determine why only three of the four circuit breakers tripped, all four were submitted to the Materials Integrity Branch at Wright-Patterson Air Force Base, Dayton, Ohio, for further examination. The circuit breakers were visually examined and were subjected to an insulation resistance measurement, a contact resistance test, a voltage drop test, and a calibration test (which measured minimum and maximum ultimate trip times). Testing and examination determined that the circuit breaker that did not trip exhibited no anomalies that would prevent normal operation, met all specifications required for the selected tests, and operated properly during the calibration test. Although this circuit breaker appeared to have functioned properly during testing, the lab report noted that, as a thermal device, the circuit breaker is designed to trip when a sustained current overload exists and that it is possible during the event that intermittent arcing or a resistive short occurred or that the circuit opened before the breaker reached a temperature sufficient to trip the device.
Quoted verbatim from the NTSB record.
Other Douglas DC-9 accidents
| Date | Aircraft | Location | Operator | Outcome | Died |
|---|---|---|---|---|---|
| 29 Nov 2000 | Douglas DC-9 | Atlanta, Georgia, United States | Airtran Airways Inc | Minor injuries | - |
| 6 Oct 2000 | Douglas DC-9-31 | Reynosa, Mexico | Aerovias de Mexico S.a. | Fatal | - |
| 1 May 2001 | Douglas DC-9-31 | Minneapolis, Minnesota, United States | - | Minor injuries | - |
| 15 Jan 1999 | Douglas DC-9 | Plainfield, Pennsylvania, United States | - | Serious injuries | - |
| 10 Nov 1999 | Douglas DC-9-31 | Uruapan, Mexico | Transportes Aereos Ejecutivos | Fatal | 18 |
| 5 Mar 1999 | Douglas DC-9-15F | Kansas City, Missouri, United States | - | No injuries | - |
Other accidents in this area
| Date | Aircraft | Location | Operator | Outcome | Died |
|---|---|---|---|---|---|
| 26 May 2000 | John Thomas CLOUD DANCER 2 | Franklin, North Carolina, United States | - | No injuries | - |
| 23 Sep 2000 | Piper PA-22-135 | Enochville, North Carolina, United States | - | Serious injuries | - |
| 10 Mar 2000 | Cessna 172L | Beaufort, North Carolina, United States | - | No injuries | - |
| 10 Jul 2000 | Cessna 172L | Beaufort, North Carolina, United States | - | No injuries | - |
| 26 Sep 2000 | Douglas DC-3 | Charlotte, North Carolina, United States | - | No injuries | - |
| 20 Nov 2000 | Aerospatiale ATR-72-212 | Ashevelle, North Carolina, United States | - | Serious injuries | - |